Description

The BDN detection unit is designed to search, detect and localize sources of neutron radiation, as well as to measure the ambient dose equivalent rate (DER) of neutron radiation in collimated Pu-a-Be radiation.

 

Operating principle

Operating modes:

  • measurement of neutron radiation DER
  • search for sources of neutron radiation
  • programming operating modes

 

The BDN provides input, storage in non-volatile memory and continuous monitoring of the achievement or exceeding of two DER threshold levels, as well as sound and light alarms when the established threshold levels are exceeded.

 

Work as part of a complex device and with a PC

When connected to the detection and information processing unit of the BDOI-RM1403 dosimeter-radiometer, the information display unit of the BOI-RM1403 dosimeter-radiometer or to a personal computer (PC), the following is carried out:

  • indication on the display of the measured value of neutron radiation DER and indication of the relative root-mean-square error of the average value of the measurement result with a probability of 0.95 (statistical error) in percent;
  • indication of the average counting rate and the measured value of the neutron radiation DER when the BDN is operating in the search mode;
  • programming of operating modes of the BDN.

BDN connects to BDOI/BOI or PC via RS-485 or USB interface

 

Other detection units for working with BDOI

BDG2 – GM detector, gamma radiation detection unit

BDG3 – Csl(TI) detector, gamma radiation detection unit

BDAB – proportional counter, alpha and beta detection unit

 

Applications

Geological exploration work

Surface contamination control

Laboratory control

Control of radiological cleanliness of workplaces

 

Compliance

For electromagnetic compatibility, it complies with STB IEC 61000-6-2-2011, STB IEC 61000-6-3-2012, STB GOST R 51522-2001

The level of radiated radio interference complies with the requirements of STB EN 55022-2012 (class B)

 

 

Detector He-3
DER measurement range from 1.0 to 5000 μSv/h (according to Pu-α-Be source in collimated radiation)
Limit of permissible main relative error of DER measurement ± (30+K/Ḣ)%, where Ḣ – DER value, μSv/h; K – coefficient equal to 10.0 μSv/h
Sensitivity to neutron radiation:
for Pu-α-Be 0.65 imp cm2
for thermal neutrons 4.5 imp cm2
Energy range of detected neutron radiation from thermal (0.025∙10-6 MeV) to 14.0 MeV
Data exchange:
BDOI/FIGHTING RS-485
PC USB
Supply voltage 3.7 V (- 0.1; + 0.5) V
Housing protection degree IP65
Operating temperature range from -20 to +50 °C
Atmospheric pressure from 84 to 106.7 kPa
Relative humidity up to 95% at 35 °C
The device is resistant to falling onto a concrete floor from a height 0.7 m on concrete floor
Physical parameters:
Weight 0.7 kg
Dimensions 230 x 63 mm
Average service life at least 10 years

Delivery methods: delivery to the address, delivery by transport companies. We deliver throughout Russia. Delivery prices are calculated by sales managers. Delivery times are calculated depending on the equipment supplied and the conditions specified in the contract. Payment methods: We accept non-cash payments including VAT.

Go to the equipment catalog