Individual dosimeter for x-ray and gamma radiation DKG-RM1610A-01
The electronic direct-reading dosimeter DKG-RM1610A-01 measures the equivalent dose and power of X-ray and gamma radiation. The device is designed to monitor the radiation situation and prevent personnel from radiation contamination.
The main differences between the DKG-RM1610A-01 model and the basic model PM1610:
– availability of a data transmission channel in accordance with the ISO15693 standard;
– reduced limits of the permissible basic relative measurement error of the permissible zone;
– extended measurement range.
Dosimeters of this series have the following advantages:
– miniature weight;
– ease of operation;
– impact resistance: resistant to falling from a height of 1.5 meters onto a concrete surface due to the rubberized body;
– the presence of two independent alarm thresholds for both equivalent dose and power;
– presence of vibration, sound and light alarms.
Applications:
- Medicine.
- Customs and border control.
- Individual radiation safety.
- Nuclear industry enterprises.
- Enterprises for processing or transporting products containing radioactive materials.
- Environmental monitoring.
Performance characteristics (TTX): Individual dosimeter for x-ray and gamma radiation DKG-RM1610A-01
| Name: | Meaning: |
| Detector | Geiger-Muller counter |
| Measuring range: | |
| Equivalent dose | Continuous radiation:
0.05 µSv ÷ 20 Sv Pulse radiation: 10 µSv ÷ 20 Sv |
| Equivalent dose rates | 0.1 μSv/h ÷ 10 Sv/h |
| Display range: | |
| Equivalent dose | 0.001 µSv ÷ 24 Sv |
| Equivalent dose rates | 0.01 μSv/h ÷ 12 Sv/h |
| Limit of permissible basic relative measurement error: | |
| Equivalent dose | No more than ± 20% |
| Continuous equivalent dose rates and average equivalent dose rates of pulsed photon radiation | No more than ± (10+K1/H+K2⋅H) %, where H is the equivalent dose rate |
| Energy range of photon radiation | 20 keV ÷ 10 MeV |
| Energy dependence relative to energy 0.662 MeV: | 20 keV ÷ 33 keV: – 60%
33 keV ÷ 48 keV: – 40% 48 keV ÷ 3 MeV: ± 30% 3 MeV ÷ 10 MeV: ± 50% |
| Threshold | 2 in the entire range of DE and DER |
| Alarm type | Visual, sound, vibration |
| Housing protection degree | IP65 |
| Operating temperatures | – 20 ÷ +50 °C |
| Nutrition | Built-in rechargeable battery; external power supply |
| Average continuous operation time with one set of batteries | At least 30 days |
| PC connection | USB, ISO15693 interface |
| Dimensions, weight | 58x59x20 mm, 70 g |
| Relative humidity | Up to 98% at 35°C |
Delivery methods: delivery to the address, delivery by transport companies. We deliver throughout Russia. Delivery prices are calculated by sales managers. Delivery times are calculated depending on the equipment supplied and the conditions specified in the contract. Payment methods: We accept non-cash payments including VAT.